S1000_01
S1000_02S1000_07S1000_12S1000_09S1000_13S1000_16

Stromtank S1000

International specifications

Input AC parameters on grid

Input voltage range : 50 to 140 Vac / 150 to 265 Vac

Input frequency  : 45 to 65 Hz (auto sensing)

Input current max. : 16 Aac (transfer relay)

Input current adjusted : 10 Aac (115Vac), 10 Aac (230Vac) – factory setting

transfer time :  < 15 ms, on grid to off grid

Output AC :  parameter off grid

Output voltage : 100-130Vac / 200-245Vac (pure sine wave +/- 2%)

Output frequency : 50 Hz / 60 Hz +/- 0.05% (crystal controlled)

Harmonic distortion : < 2%

Continues power @ 25°C : 450 VA

Power 30min. @ 25°C : 700 VA

Battery power unit

Battery type : LFP – Lithium Iron Phosphate (LiFePO4)

We reserve the right to make any modifications to the product without prior notification.

Typical charge current 8 Adc – factory setting

Working temperature : 0 to 45°C, 32 to 113°F

Emergency charge current : 3 Adc (special STROMTANK charger necessitated)*

Battery Management System : Flex-BMS, single cell control, active balancing 5A

Terminal area

AC output receptacles : 4 x Hubbell duplex, Hospital spec. grade

4 x Furutech High performance Schuko sockets

AC output fuse : thermal – magnetic circuit breaker

AC input connection : ICE 320 – C14 (fuse 16/10AT)

Interface : CAN (RJ45-8 type “Com bus”)*, USB*

Charge connector : use STROMTANK charger only

Power switch : on/off (“on” = green LED)

Safety key switch : key switch “Release/Lock” all functions**

Additional Features

Color meteorit-gray (other colors on request)

Weight 41 kg / 90 lbs

Dimension (w x h x d) 48 x 22 x 47 cm / 19 x 9 x 19 inches

 

Category: .